Home > Products > single point load cell >

IN-PW15AH 10 to 100kg Single Point Load Cell for platform scale

IN-PW15AH 10 to 100kg Single Point Load Cell for platform scale

IN-PW15AH 10 to 100kg Single Point Load Cell for platform scale
Categoriessingle point load cell
AlbumView larger image
BrandHUAZHUN
ModelIN-PW15AH
load cell typesingle point type
materialstainless steel
capacity10 to 100kg
Sensitivity2.0±0.2
AccuracyC3 Multi Range (MR)
Input impedance300 ... 500
Output impedance330 ... 500
Zero balance0±0.1
IP RatingIP68;IP69K
Applicationplatform scale
FOB portshanghai
Terms of PaymentL/C
Download DOC
Update Time2018-12-13
Detail Information
IN-PW15AH 10 to 100kg Single Point Load Cell 
for platform scale


Special features
- Hermetically sealed(IP68; IP69K)
- highest reliability
- Reduced minimum load cell verification interval(V min) for multi range applications
- Interchangeable to products of many manufacturers
- Stainless steel
- 6-wire-technology
- Integrated connection for protective cable conduit systems



Type

PW15AH

Accuracy class1)

C3 Multi Range (MR)

Number of load cell intervals (nLC)

3000

Maximum capacity (Emax)2))

kg

10

20

50

100

Minimum LC verification interval

g

1

2

5

10

Temperature effect on

zero balance

% v.

Cn /

10 K

 

±0.0140

±0.0140

±0.0140

±0.0140

Max. platform size

mm

500 x 400

Sensitivity (Cn)

mV/V

2.0±0.2

Zero balance

0±0.1

Temperature effect on

sensitivity (TKC)3)

Temperature range

+20 ... +40  [+68 ... +104]

−10 ... +20  [+14 ... +68]

% v.

Cn /

10 K

 

±0.0175

±0.0117

Hysteresis error (dhy)3)

% of Cn

±0.0166

Non-linearity (dlin)3)

±0.0166

Minimum dead load output return (DR)

±0.0166

Off center load error4)

±0.0233

Input resistance (RLC)

Ω

300 ... 500

Output resistance (R0)

330 ... 500

Reference excitation voltage (Uref)

V

5

Nominal range of excitation voltage (BU)

1...12

Max. excitation voltage

15

Insulation resistance (Ris) at 100 VDC

1

Nominal temp. range (BT)

°C

[°F]

−10 ... +40 [+14 ... +104]

Service temp. range  (Btu)

−10 ... +50 [+14 ... +122]

Storage temp. range (Btl)

−25 ... +70 [−13 ... +158]

Safe load limit (EL ),

% of

Emax

150

at max. eccentricity

mm

160

Lateral load limit (Elq), static

% of

Emax

300

Breaking load (Ed)

300

Deflection at Emax (snom), approx.

mm

< 0.5

Weight (G), approx.

kg

1.0

Protection class according to

EN 60 529 (IEC 529)

 

IP68(test conditions 100 h at 1m water column);IP69K(water at high presure,steam jet cleaning)

Material: Measuring element

Coating

Cable sheath

 

C1.4545

Silicone rubber

                                                                   PVC

Please send your message to us
*We will reply your inquiry to this Email as soon as we see it
*Email
Name
Tel
*Title
*Content

Agree to use terms of service